Microprism Light Guide
>>Flat Light Guide
>>Wedge Light Guide
>>Dual Mode Light Guide
>>Viewibg Area Expander Backlight
CCFL Lamps
>>Lamp Specification
>>Sample Quality Control Manual
CCFL Inventers
Optical Films
NVIS filter
LED PC Board
LED Driver |
|
|
|
|
Sample Lamp Quality Control Manual |
|
|
|
- Introduction
Testing Instruments & Conditions
Basic Specifications
Testing Schematics
Life Testing
Reliability Testing
Inspections & AQL
Packing & Marking
|
|
|
|
|
|
Introduction:
- Descriptions:
- The product CCFL I26-350,is designed as the light source for backlight module of 1 7"LCD monitor, and its color chromaticity are set ad X=0.30±0.0 1; Y=0.285±0.01.
Lighting principles:
Clio's CCFL is made of miniature hard-glass tube, which spread with high-performance Tri-color fluorescent powder on inner surface and filled in idle-gad & less of mercury vapour, when powered it on, the gas was dissociated to stimulate the mercury vapour and emission out 253.7nm ultra-violet rays, and then changed to visible light when passed through fluorescent coating layer.
- Product Characteristics:
- High luminance & efficiency, low power consumption, small size and long life.
- Good impact absorbability, start ability & Repeatability
- Can be instantly started on under 0.1 Lx illuminations.
- Color temperature Tri-colors can be adjusted on customer's requirements.
- Applications:
- LCD monitor back-light source.
- Ambient conditions for applications:
- For operation:
Themperature: 0~60 °C
Relative humidity: 20~90%
No condensation or iced on lamp surface.
- For storage: ~p
Temperature: -30~70 °C
Relative humidity: 5~90%
No condensation or iced on lamp surface.
- Notices:
- Don't bend both-ends electrodes, or it may influence vacuum characteristics and break-down the lamp.
- Don't bend, curve or shock on lamps or it may be broken.
- It may be shorten average life when using lamps in low temperature
(< 0 °C ) environments.
- For preventing electric-shock, don't touch both-ends electrodes of lamps while power it on.
- When welding wire to electrode, should be finished in a short time for preventing overheat and breakage of lamps.
- Don't look at lamp for a long time when lighting, or it may hurt eyes.
top
|
|
|
|
|
|
Testing instruments and conditions:
- Testing instruments:
- Mili-ampare meter: INSTEK GDM-8246A
- RMS meter: INSTEK GDS820C
- High-voltage probe: TEK P6015A
- Luminance meter; TOPCON BM-7
Testing conditions:
- Temperature:25±2 °C
- Relative humidty:65%±20%(no wind)
- Start testing after lighting 5 minutes.
-
Notices:
- Don't mis-connecting the positive/negative poles of inverter.
- Don't touch instruments while on, testing
top
|
|
|
Basic Specifications
Size and Dimensions:

-
- Materials List
-
No. |
Part Names |
Materials |
Remarks |
1 |
Electrode guide-pin |
Ni |
- |
2 |
Glass tube |
Hard-glass |
- |
3 |
Flourescent Powder |
Tir-Colors
Flourescent Powder |
- |
4 |
Filling gas |
Ne+Ar |
- |
5 |
Electrode |
Ni |
- |
6 |
Degasnater |
Al-Zr |
- |
7 |
Rubber cap |
- |
- |
8 |
Connector |
- |
- |
9 |
Wire assy |
- |
- |
Initial Characteristics:
No. |
Items |
Specifications |
Remarks |
1 |
Color temperature |
8000k(ref.) |
Tube current at 5mA |
2 |
Color chromaticty |
X=0.300±0.01
Y=0.285±0.01 |
Checking the central section of lamps with TOPCON BM-7 |
3 |
Main ray wave length |
R=611
G=544
B=453 |
Checking the central section of lamps at tube current 5mA |
4 |
Tube current |
5mA |
Measured with GDM-8246 |
5 |
Tube voltage |
690V±10%ms |
Measured with TOPCON BM-7 |
6 |
Power(ref.) |
3.45W |
At input voltage 12VDC |
7 |
Surface luminance |
33000±10%cd/m2 |
Measured with TOPCON BM-7 |
8 |
Effective lighting length |
300mm |
Total length of lamp which luminance over 80% of it at central section |
9 |
Startup voltage |
1050 Vrms max. |
At ambient temp. 25±2°C |
10 |
Startup time |
500ms max. |
Testing after lain in room temp. 25±2°C for 2 hrs later |
11 |
Stable dicharging time |
3min |
100% luminance at lamp central section after power on 5 minutes |
12 |
Life |
25000hrs |
Ambient without wind |
13 |
Dimension |
OD=2.6±0.1mm
ID=2.0mm |
Lamp length 350±1.0mm |
Remarks:
- Testing conditions for luminance & chromaticity:
- Tube current:SmA
- Frepuency:50±l0kHZ
- Instrument: TOPCON BM-7 0. 1° field angle.
- Testing distance:5000±50mm
- Environments: Ambient temperature 25±2°C, R.H 35~85% without wind & light
- Testing time: To do testing after power on 3 minutes
|
top |
|
|
Testing Schematics
Lamp Current Testing:
- Wire length of A-B:150±10mm
- Wire length of C-D:300±10mm
- Measurement item: Lamp current
- Instruments: Lamp current mili-ampare meter GDM-8246
Lamp Voltage Testing:
- Wire length of A-B:150±10mm
- Wire length of C-D:300±10mm
- Measurement item: Lamp voltage
- Instruments: RMS meter GDS-820C & high voltage probe TEK P6015A
Brightness & Chromaticty:
Luminance meter: TOPCON BM-7 field 0.1°
Notes:
- Tube current: 5mA
- Frequency: 50±10kHz
- Instrument: TOPCON BM-7 field 0.1°
- Testing distance: 500±50mm
- Environments: Ambient temperature 25±2°C, R.H. 35~85% without wind & light
- Testing time: To do testing after power on 3 minutes
|
|
|
top |
|
|
Life Testing:
- Judging conditions:
- If one of the following conditions occurred the lamp life is over.
- The luminance of lamp central section becomes less then 50% of initial value.
- Starting voltage is higher than the rated voltage.
Testing items:
- Rated life: Rated life is the testing time when the rest good lamps equal to 50% of total
testing conditions:
Testing conditions:
Ambient temperature: normal(25°C)
Current : 5rnA
Power on frequency: continuous
- Low temperature life:
Testing conditions: Low temperature life
Ambient temperature:0°C±1°C
Current :5mA
Power on frequency: continuous
- On-off life:
Testing conditions:
Current :5mA
Cycle time :l0sec. on and 10sec.off
|
|
Rated Life
25,000Hrs |
Rated Life
500Hrs |
Rated Life
200,000 |
Application Environments:
Items |
Specifications |
Remarks |
Operation temperature |
0°C~60°C |
No condensation |
Storage temperature |
-30°C~70°C |
Relative humidity |
90% |
|
|
|
top |
|
|
Reliability Testing
- Lamps need to fulfill the following
reliability tests items:
No. |
Items |
Conditions |
Specifications |
1 |
Impact testing |
6.3.1 |
C,E |
2 |
vibration testing |
6.3.2 |
C,E |
3 |
Terminal tensil strength testing |
6.3.3 |
C,E |
4 |
Heat-cycle testing |
6.3.4 |
A,C,D,E |
5 |
High temperature & humidity testing |
6.3.5 |
A,B,C,D,F |
6 |
High temperature testing |
6.3.6 |
A,C,D,F |
7 |
Low temperature testing |
6.3.7 |
A,B,C,D,F |
8 |
High temperature & humidity operation testing |
6.3.8 |
A,B,C,D,F |
9 |
Seal up testing |
6.3.9 |
C,D,E |
10 |
Snaking testing |
6.3.10 |
G |
11 |
Low temperature operation testing |
6.3.11 |
A,B,C,D,F |
- Notes:
- According to paragraph 6.3 to do each testing
- The details of specifications are listed in paragraph 6.2
- No lighting during each testing except No. 3,8,11
|
-
-
- Judging Conditions
-
- After reliability testing, the characteristics of testing lamps must be met the following requirements:
- Startup voltage: No over 10% of initial value.
- Luminance: At least 50% of initial value.
- No mechanical or physical damage (e.g. nickel guide pin broken)
- No visible distortion, colorchanging etc.
- No lamp can't light up.
- The luminance should be up to 95% of it stability, after power on 3 minutes.
- No darken, color changing in appearance, or unnormal lighting (flicking smacking etc)
Testing Conditions:
- Pulse wave of 30G, llm/sec2 should be applied three times each in X,Y,Z directions.The lamp should be held on the testing fixture.
- Acceleration 19.6m/sec2,frequency 20-500-20Hz be applied in 3 minutes each time, and each In X,Y,Z directions for lhr. Be careful to prevent resonant point.
- Terminal wire intensity test:
- Tube axial load: lkg
Time:5 sec.
- Heat-cycle test:
- Operating 10 cycles as following condition
- High-temperature & humidity storage test:
- Temperature:70±2°C
Humidity: 90±5%R.H
Time: 500hrs
The lamps should be preserved at room temperature for 2 hrs before doing function testing.
- High temperature storage test:
- Temperature: 70±2O°C (Dry)
Time: 1000hrs
The lamps should be preserved at room temperature for 2 hrs before doing function testing.
- Low-temperature storage test:
- Temperature: -30°C ±2O°C
Time: 1000hrs
The lamps should be preserved at room temperature for 2 hrs before doing function testing.
- High-temperature & humidity operating test
- Temperature: 40±°C
- Humidity: 90%R.H
- Time: 5mA
- Current: 5mA
- Sampling 40pcs dipped in the boiling water(>95°C) for 10 sec, then dipped in 4°C water for 10 sec. Doing cycle 3 times. All samples should be passed, if there is one fail, do the Next test again.
- Snaking test:
- Temperature: 50±2°C
Time: 24hrs
Current:5mA
The lamps should be preserved at >0°C ±2 temperature for 2 hrs before doing function
testing.
- Low-temperature operation test:
- Temperature:0±1°C Time: 5mA The lamps should be preserved at room temperature for 2 hrs before doing function testing. testing.
|
|
|
top |
|
|
Inspection & AQL
(Acceptable Quality Level)
- Lamp Quality Control
- In order to control the lamp's quality, according to CNS 2779 Z4006 table II -A ~single sampling plans of normal inspection to do the quality control.
- Bad quality: Snaking, flicker, crack (No external force)
- Light bad quality: Fluorescent coating cracked & peeled off
- Remark:
- Hg sticked on inner wall of tube is normal.
- Light black color of two end-sides of glass tube is normal.
- Fluorescent coating peeled off in 15mm from two end-sides is not counted.
Inspection Items |
AQL |
Inspection Methods |
Appearance of Lighting |
Bad quality AQL<0.4 |
Vision |
Light bad quality AQL<0.5 |
Mechanical dimensions |
N=5, C=0 |
Measuring tools |
Initial characteristics |
N=5, C=0
(AQL 0.4) |
According to 3,4 paragraph |
|
|
|
top |
|
|
Packing & Marking
- According to the standard of packing requirements of BriteView Technologies Inc.
-
-
-
-
-
-
-
|
|
|
top |
|
|
|